fit tester from occupational health dynamics
Home    Contact    Overview    Technical    Articles    FAQ fit tester
     
     
 
fit tester

How the Fit Tester Works

Here’s how the Fit Tester 3000 works. During a fit test, the respirator inlets are capped with test adapters, and the inhalation valves are removed from the mask. With the test subject holding his or her breath for no more than ten seconds, Fit Tester 3000 then establishes and maintains a slight vacuum, or controlled negative pressure, inside the mask. Since the respi-rator inlets are sealed, all sources of leakage into the mask are through the face-to-facepiece seal. The volume of air drawn out of the mask by FitTester 3000 during this short time period is equal to the leak rate into the mask through the face-to-facepiece seal. It’s that simple...

 

 

Specifications

   
  Dynamic Range
Leak Test Measurement 2 - 4500 cc/min
    Fit Factor Computation 10 - 53,000
       
  Pressure Sensors Pressure Range 0 - 10 inches H20
    Accuracy +/- 0.5% full scale
    Over-Pressure Limit + /- 5%
       
  Instrument Accuracy Challenge Pressure +/- 5%
    Leak Rate Measurement +/- 3% or +/- 3 ml/min
(from 10 - 4500 cc/min)
       
  General Specifications Size 12.5" L x 5" H x 15" D
31.8 cm L x 12.7cm H x
38.1cm D
    Weight 15 Ibs / 6.88 kg.
    Power 110/220 VAC
(User Configurable)
50 Watts, 50/60 Hz.
       
  Standard Accessories Soft Vinyl Accessory Pouch;
Power Cord (Country Specific);
Squeeze Bulb Assembly Probe;
Cal Adapter User;
Dual Tube Assembly;
Manual
 

For more detailed specifications please download the Fit Tester Datasheet (PDF, 1.4Mb)

 

 
     